PO.CL01.04 · 临床研究

ddPLEX EGFR/KRAS/BRAF: A highly multiplexed droplet digital PCR (ddPCR) panel for ultra-sensitive NSCLC biomarker detection

海报缩略图:ddPLEX EGFR/KRAS/BRAF: A highly multiplexed droplet digital PCR (ddPCR) panel for ultra-sensitive NSCLC biomarker detection
编号 3743 展板 15 时间 4/20 02:00–05:00 区域 Section 41 主讲 Surbhi Jain, PhD
分会场 Biomarkers Predictive of Therapeutic Benefit 4
查看完整资料 下载 PDF 登录后可访问当前开放资料 AACR 官方页面 ↗

作者与单位

Surbhi Jain1, Cailin Festog1, Mai Ho1, Cindy Li1, Necip Mehmet1, Ady Melendez-Molina1, Toshiro Newsum1, Prithwish Pal1, Mina Rostamza1, Yusuke Ono2, Leisa Jackson3, Brittany D’Alessio3, Gunnar Johnson3, Gary A. Pestano3

1Bio-Rad Laboratories, Hercules, CA,2Sapporo Higashi Tokushukai Hospital, Sapporo, Japan,3Biodesix, Inc., Louisville, CO

摘要 Abstract

Biomarker testing for actionable oncogenic driver mutations is recommended in national and international guidelines based on the improved outcomes observed with use of targeted therapies in eligible patients with metastatic NSCLC. Here, we demonstrate the performance of the ddPLEX EGFR/KRAS/BRAF Mutation Detection Assay Kit, a research use only kit developed for the QX600 TM Droplet Digital TM PCR (ddPCR) System. This kit is designed for the detection, discrimination and quantification of 37 actionable variants in the EGFR , KRAS , and BRAF genes in a single ddPCR well. It also has a companion total quantification well that quantifies EGFR , KRAS and BRAF genes in a mutation agnostic manner and allows for variant allele frequency (VAF) calculation. It provides same day results with a streamlined workflow, includes positive and internal controls and is compatible with plasma and formalin-fixed paraffin-embedded (FFPE) samples. The analytical performance of the ddPLEX EGFR/KRAS/BRAF Mutation Detection Assay Kit was evaluated internally, and the findings are presented here. The results demonstrated an analytical sensitivity of 0.025%-0.1% in a background of 132 ng of human genomic DNA for all targeted variants. The assay had an analytical specificity of 100% when tested with 1000 copies input of each variant, one at a time, in a total of 132 ng of human genomic DNA. The mutant assay did not cross-react with any of the commonly reported mutations located in the same amplicon as KRAS G12C and BRAF V600E. The mutant assay was linear from 800 copies to 4 copies per reaction with a R 2 in the range of 0.94-0.99. The total quantification assay was also linear in the range of 1.3 ng to 53 ng of total DNA input with a R 2 >0.99 for all three targets. With previously extracted and archived cell-free DNA from plasma and FFPE DNA that were tested with alternative PCR based methods, the ddPLEX kit had a concordance of 100% and 96.5%, respectively. In conclusion, the ddPLEX EGFR/KRAS/BRAF Mutation Detection Assay Kit is sensitive, accurate, and efficient in time and cost for detecting clinically relevant NSCLC variants. Multiplexing maximizes information and reduces sampling bias from specimens with low nucleic acid quantities such as FFPE and plasma.
利益披露 Disclosure
S. Jain, None.. C. Festog, None.. M. Ho, None.. C. Li, None.. N. Mehmet, None.. A. Melendez-Molina, None.. T. Newsum, None.. P. Pal, None.. M. Rostamza, None.. Y. Ono, None.. L. Jackson, None.. B. D’Alessio, None.. G. Johnson, None.. G. A. Pestano, None.

在会议检索中打开